This highly versatile, competitively-priced, multi-channel,
multi-display meter is easy to set up and use while
delivering exceptional, long-life performance for demanding
R&D and QA/QC applications. The rugged meter offers a full
complement of GLP-related features?including 21 CFR Part 11
software.
|
pH : |
|
|
Range/ Resolution : |
–2.000 to 19.999 or 0 to 14 in aqueous solutions /
0.1,0.01,0.001 |
|
Relative accuracy : |
+/- 0.002 |
|
SMART STABILITY™ and SMART AVERAGING™ : |
Resolution dependent / automatic |
|
AUTO-CAL™ and/or Manual Calibration : |
1
to 5 points; US/NIST, DIN, and custom buffers recognized
|
|
ISE : |
|
|
Range/Resolution : |
0
to 19900 / 1,2, or 3 significant digits |
|
Relative Accuracy : |
+/- 0.2mV or 0.05%, whichever is greater |
|
SMART STABILITY™ and SMART AVERAGING™ : |
Resolution dependent / automatic |
|
Units : |
M,
mg/L, %, ppb, or no units |
|
# ISE Cal points : |
1
to 5 |
|
Special ISE Calibration Features : |
Linear point to point, selectable auto-blank non-linear,
low concentration range |
|
mV : |
|
|
Range – mV / RmV : |
±
1999.9 |
|
ORP : |
EH
autocalibration to standard hydrogen electrode |
|
Resolution : |
0.1 |
|
Relative Accuracy : |
±
0.2 mV or 0.05%, whichever is greater |
|
Conductivity : |
|
|
Range : |
0.000 to 3000 mS/cm, auto resolution with cell constant
dependence |
|
Resolution : |
4
significant digits down to 0.001 µS/cm, cell constant
dependent |
|
Relative Accuracy : |
0.5% ± 1 digit or 0.01 µS/cm, whichever is greater |
|
Cell Constant : |
0.001 to 199.9 |
|
Cell Compatibility : |
2
Cell, 4 Cell, Planar Cell |
|
SMART STABILITY™ and SMART AVERAGING™ : |
Resolution dependent / automatic |
|
DirectCal™ / AUTO-CAL™ : |
1
to 5 points / 1 to 3 points |
|
Resistivity : |
|
|
Range / Resolution : |
0.0001 to 100 Megohm / Auto resolution |
|
Relative Accuracy : |
0.5 % ± 1 digit |
|
Salinity : |
|
|
Range / Resolution : |
0.1 to 80.0 ppt NaCl equivalent, 0.1 to 42ppt practical
salinity / 0.1 |
|
Relative Accuracy : |
±
0.1 ± 1 digit |
|
TDS : |
|
|
Range / Resolution : |
0
to 19999 / 1 mg/L |
|
Relative Accuracy : |
±
0.5 % ± 1 digit |
|
Adjustable TDS Factor : |
0.00 to 10.00 |
|
DO : |
|
|
Range / Resolution Concentration : |
0.00 to 90.0 mg/L / 0.0/0.00 |
|
Range / Resolution % Saturation : |
0.0 to 600% / 0/0.0 |
|
Relative Accuracy Concentration / % Saturation : |
±
0.5% ±1 digit |
|
SMART STABILITY™ and SMART AVERAGING™ : |
Resolution dependent / automatic |
|
Auto Calibration or Manual Input : |
Water Saturated Air and Air Saturated Water, Winkler |
|
Calibration to Winkler Titration for BOD : |
Available as needed |
|
Salinity Factor : |
0
to 45 ppt |
|
Barometric Pressure Range : |
450 to 850 mm Hg |
|
Probe Type : |
Polarographic |
|
Temperature : |
|
|
Range / Resolution : |
-5
to 105ºC / 0.1 up to 99.9ºC, 1.0 over 99.9ºC |
|
Relative Accuracy : |
±
0.1 ºC |
|
Temperature Compensation : |
DO
(auto); Cond (nLF, linear 0.0 to 10.0% /ºC); pH
(auto/manual) |
|
Display : |
Custom backlit LCD, for easy viewing |
|
Inputs/Outputs : |
|
|
Sensor Inputs : |
Conductivity-miniDIN - Locking; DO-miniDIN - Locking;
ATC-miniDIN-Locking; pH/ISE - BNC; Reference-Pin tip;
Stirrer-Phono-jack |
|
# Of Data Logging Points : |
200 points by time, stability or manual read with
time/date stamp |
|
Calibration Log : |
Last 10 Calibrations |
|
User Method Storage : |
10
Saved |
|
Advanced Self-test and Diagnostics : |
YES |
|
GLP Electrode Verification : |
YES |
|
Password Protection : |
YES |
|
Internet Software Updates / Downloadable Methods : |
YES |
|
21 CFR Part 11 Software Package : |
YES |
|
Power : |
Universal power adapter and battery power 4 x AA
batteries |
|
Regulatory and Safety : |
CE, CSA, UL, TÜV, FCC Class A limits |
|
Environmental Operating Conditions : |
|
|
Ambient Operating Temperature : |
5
to 45ºC |
|
Relative Humidity : |
5
to 85% Non-Condensing |
|
IP Rating : |
IP54, splashproof and dustproof |
|
Warranty : |
36
months (from date of purchase) |